Modern IT workloads are increasingly growing in complexity from the demands of today’s highly digitalised world. To meet these challenges, enterprises are turning to multi-cloud strategies, and rolling out versatile converged infrastructure and powerful high-performance computing (HPC) systems to drive new applications and capabilities.
StarHub partners with AirTrunk for its new hyperscale data centre campus (AirTrunk SGP1) at Loyang, the largest carrier-neutral data centre in Singapore. The campus is strategically close to Changi Cable Landing Station - Singapore’s largest cable landing station, and the terminal for several major submarine cables connecting Singapore to other parts of the world. Design PUE of 1.3, StarHub Hyperscale Data Centre @ Loyang (SHDC@Loyang) delivers high energy efficiency using innovative and highly efficient cooling systems to meet customers’ requirements of high energy efficiency and scalability.
Built to the industry’s highest certified standards, this state-of-the-art hyperscale data centre is expected to meet the requirements for ISO 27001, PCI-DSS, BCA-IMDA Green Mark Platinum certification and Threat and Vulnerability Risk Assessment (TVRA).

Our hyperscale facilities provide flexibility, interconnected ecosystem, one-stop managed services and power efficiency to help your enterprise maximises potential.

Power Efficiency

One-Stop Managed Services

Flexibility

Interconnected Ecosystem

High Scalability

High Cooling Efficiency

Next- Gen Computing

Power
- Dual incoming power feeds with N+N redundancy and diverse path
- Support up to 24kW per rack without additional cooling systems
- Diesel generators with 24-hour back up time
- Flexible power distribution architecture based on busways
- Design PUE of 1.3

Cooling
- N+2 Indirect Evaporative Cooling (IEC) units
- Evaporative process water storage tanks sized for 24-hour water storage on-site
- Hot-aisle containment with supply air from 2 sides of data halls

Fire Suppression System
- Individual fire detection zones
- Early smoke detection system
- Pre-action sprinkler system
- Smoke and heat detection sensors
- Fire-rated doors and partitions

Security
- Threat and Vulnerability Risk Assessment (TVRA)
- Anti-climb perimeter fencing
- Two-factor verification for data hall access
- Turnstiles to prevent tailgating
- 24 x 7 IP cameras monitoring of internal and external areas

Connectivity
- Carrier Neutral
- Access to global Tier-1 carriers
- Close physical proximity to Changi Cable Landing Station
- Diverse lead-in pipes into the building
- Redundant Meet Me Rooms (MMR)
Higher-tier / Large enterprise customers that require:
- A minimum power density of 6kW per rack and up to 24kW per rack
- Supports higher rack size
- Growing infrastructure needs for future growth